Первая
<table style="border-collapse: collapse; width: 100%;"> <tbody> <tr> <td style="width: 50%;">Measuring range* / sensing element</td> <td style="width: 50%;">(-200 ÷ 150) ºC / Pt100 / class B</td> </tr> <tr> <td style="width: 50%;">Measuring insert p. 43÷44</td> <td style="width: 50%;"> <ul> <li>tube W1 or mineral insulated W2 and W3</li> <li>2-, 3-, 4-wire connection (for Pt100)</li> <li>2-, 3-wire connection (for 2xPt100)</li> <li>insert length: Lw=L+155 mm</li> </ul> </td> </tr> <tr> <td style="width: 50%;">material</td> <td style="width: 50%;">steel 1.4541</td> </tr> <tr> <td style="width: 50%;">length L [mm]</td> <td style="width: 50%;">50÷2000</td> </tr> <tr> <td style="width: 50%;">Connection head</td> <td style="width: 50%;">BA, IP55, (-40 ÷ 100) ºC</td> </tr> <tr> <td style="width: 50%;">Options</td> <td style="width: 50%;"> <ul> <li>local display in connection head DANAWwin p. 220</li> <li>other threads (inch and metric) acc. to requirements</li> <li>Pt500, Pt1000, Ni100, Ni1000, N, T</li> <li>measuring junction types p. 13</li> <li>connection heads: p. 217÷218 (eg. stainless steel BEG; aliminium NA, IP65; aliminium NA with snap lock)</li> <li>Pt100: class A (-100 ÷ 450) ºC, class AA (-50 ÷ 250) ºC; TC: class 1</li> </ul> </td> </tr> <tr> <td style="width: 50%;">Additional accessories</td> <td style="width: 50%;"> <ul> <li>temperature transmitters p. 225÷241</li> <li>compensation cable p. 197</li> </ul> </td> </tr> </tbody> </table>
Вторая
<table id="myTable" width="100%"> <tbody> <tr> <td>Sensor type</td> <td><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">ø9</span></span></td> <td><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">ø11</span></span></td> </tr> <tr> <td><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">Pt</span></span></td> <td><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">≤33/≤95</span></span></td> <td><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">≤40/≤120</span></span></td> </tr> </tbody> </table>
Первая
<table id="myTable" width="100%"> <tbody> <tr> <td>Measuring range* / sensing element</td> <td>(-40 ÷ 550) ºC / K / class 2</td> </tr> <tr> <td>Measuring insert – p. 43÷44</td> <td> <ul> <li>tube W1 or mineral insulated W2 and W3</li> <li>insert length: L w =L+155 mm</li> </ul> </td> </tr> <tr> <td>Sheath</td> <td> <ul> <li>material: steel 1.4541</li> <li>length L [mm]: 50÷2000</li> </ul> </td> </tr> <tr> <td>Connection head</td> <td>BA, IP55, (-40 ÷ 100) ºC</td> </tr> <tr> <td>Options</td> <td> <ul> <li>local display built into the DANAWwin head connection – p. 220</li> <li>other threads (inch and metric) acc. to requirements</li> <li>measuring junction types – p. 13</li> <li>connection heads: p. 217÷218 (eg. stainless BEG; aluminium NA, IP65; NA with snap lock)</li> </ul> </td> </tr> <tr> <td>Additional accessories</td> <td>– temperature transmitters – p. 225÷241 – process protection tubes and thermowells – p. 200÷214 – compensation cables – p. 197</td> </tr> </tbody> </table>
Вторая
<table> <tbody> <tr> <td>Sensor type</td> <td>ø9</td> <td>ø11</td> </tr> <tr> <td>K insulated junction</td> <td>≤22/≤62</td> <td>≤27/≤90</td> </tr> <tr> <td>K grounded junction</td> <td>≤3/≤8</td> <td>≤6/≤15</td> </tr> </tbody> </table>
const divs = document.querySelectorAll('.view>a'); const data = []; divs.forEach((item) => { data.push(item.getAttribute('href')); }); console.log(data.join('\n'));